How to specify a Proximity Switch

What to put on an RFQ for Proximity Switch: the ratings, documents, and constraints that change the quote.

25 Oct 2026 · 3 min read · Tradinor Desk

Specification points for Proximity SwitchTRADINOR · FIGUREWhat to lock for Proximity SwitchBreaking capacityPoles and tripVoltage and frequencyMounting
Put these on the RFQ for Proximity Switch before you compare prices.

A buyer searching for Proximity Switch is usually trying to stop a bad substitute. Low-voltage distribution gear is specified by the fault level, the current, the poles, and the enclosure it sits in. The notes below are selection criteria for a Proximity Switch. They are not a catalog promise. Confirm every rating on the current datasheet, drawing, or test report for the revision you will receive.

What has to be true of Proximity Switch

Low-voltage distribution gear is specified by the fault level, the current, the poles, and the enclosure it sits in. For a Proximity Switch, start from the duty, then the interface to the rest of the machine or the room, then the document that proves the claim. A lower price that leaves one of those blank is a different product.

Proximity Switch is easy to confuse with Trunking. If the quote could be read as either, add the line that separates them: the rating, the fitment, or the standard named below. Link the drawing number to that line so receiving inspection can reject the wrong one.

Numbers that change the quote

Line What to write for Proximity Switch
Breaking capacity The fault current the device must interrupt, in kiloamperes.
Poles and trip Poles, curve or trip unit, and residual current if people are protected.
Voltage and frequency The real mains, single or three phase.
Mounting DIN rail, panel, or a stated enclosure with its IP code.
Coordination What sits upstream and downstream so the combination is selective.
Rated current Continuous current at the ambient inside the panel.

How to compare two offers

Lay both quotes for Proximity Switch on one sheet and line up breaking capacity, poles and trip, and voltage and frequency. If a cell is empty, the offer is not finished. Ask for the missing line in writing. When those match, the honest difference is lead time, the test evidence, and who carries the warranty. Do not average a fully specified Proximity Switch with a cheaper line that omitted breaking capacity.

Documents worth having before the deposit

IEC 60947 is the usual family for low-voltage switchgear. Ask which part of it the declaration uses. The file should name Proximity Switch and the revision, not only the supplier’s homepage. A factory quality certificate such as ISO 9001 can sit beside that file. It does not replace it.

Failures that show up after delivery

  • Sizing a breaker from the load current and ignoring the fault level.
  • Mixing a person-protection device with a plain miniature breaker.
  • Cutting an enclosure and assuming the IP code survived.

On a Proximity Switch, the expensive version of the first mistake is discovering it after the goods are in the crate. Put the rejection condition in the purchase order while the supplier can still restate the offer.

A worked RFQ line

Use this shape, then replace the brackets with your duty: “Proximity Switch — Write current, breaking capacity, poles, voltage, and the enclosure code.” That sentence is a template, not a rating of any brand. If a supplier’s datasheet uses different units, convert them onto this sheet so the next offer can be compared.

Where words like stainless / corrosion belong

Searches often add a constraint to Proximity Switch: stainless / corrosion, or automotive grade. Keep those on this page. Name the alloy or the coating and the chemical it must survive. Stainless is a family, not a guarantee. Automotive grade is a temperature, vibration, and documentation claim. Ask which AEC or customer spec is actually met, and for which part number. If you need a third constraint, add it as another line on the same drawing. A second URL that only swaps the adjective does not give a buyer a second fact.

Related in this section: how to specify Trunking.

Questions buyers actually ask

What should an RFQ for Proximity Switch include?

Write current, breaking capacity, poles, voltage, and the enclosure code.

Is a cheaper Proximity Switch the same part?

Only if breaking capacity, poles and trip, and the documents match. A missing line is a different offer.

Do waterproof, OEM, or IP words need their own page?

No. For Proximity Switch they are extra lines on this specification. Ask for the test or the drawing that gives the word a value.